Use cases
Ask. Spocky answers.
Seven questions operations sends you every week.
Heat pumps · Morning triage
You: Is my fleet OK this morning?
Spocky:
77 heat pumps · 6 signals · 1-min data, last 7 days · 4.6M points
since Nov 17 · 61 short runs a day, fleet 9
since Nov 17 · 48 short runs a day, fleet 9
since Nov 18 · COP 3.0, fleet curve 4.6
no data since Nov 22, 02:10
25 of 77 units are short-cycling this week (12 or more runs under 10 min a day). Send a technician to HP 661 and HP 962 first.
−75% on-site visitsHeat-pump operator, 400+ unitsRead the story
Try it on public data : Heat pumps, HeatpumpMonitor.org (opens in a new tab)Injection moulding · Diagnosis
You: Why does press 3 scrap more than press 4?
Spocky:
Presses 3 and 4, same mould · 24 signals · every cycle (42 s), 30 days · 123k cycles
- Same mould, same cycle time (42.0 s): not the settings
- Same material lot on both presses: not the resin
- Zone 3 phase ratio B/C 1.00 → 1.15 since Oct 28: check the phase C heating element
Heater phase drift foundPrecision plastics, ratio 1.00 → 1.15
Try it on public data : Injection press, Zenodo open data (opens in a new tab)Injection moulding · Early drift
You: Which mould is drifting before it makes scrap?
Spocky:
18 moulds · cushion, injection pressure, melt temperature · every cycle, 30 days · 412k cycles
M-07 cushion per shift, mm
1 of 18
moulds drifting
9 days
before the first scrap
Check ring
most likely cause
$200K saved in 6 monthsPrecision plastics, early drift detectionRead the story
Try it on public data : Injection press, Zenodo open data (opens in a new tab)Wind · Recurring report
You: Can the monthly wind report build itself?
Spocky:
6 turbines, 2.05 MW · 42 SCADA signals + met mast · 10-min data, October · 1.1M points
Wind farm report · October 2026
Every 1st, 08:00- energy
- 3,412 MWh
- availability
- 97.8%
- capacity factor
- 37.4%
- lost energy
- 74 MWh
- WTG 018
- WTG 0211
- WTG 037
- WTG 0431 · pitch faults
- WTG 059
- WTG 066
Energy checked against the substation meter
- 1 AugSent
- 1 SepSent
- 1 OctSent
- 1 NovSent
- 1 DecNext
480+ analyst hours a yearOffshore wind measurementRead the story
Try it on public data : Wind farm, Kelmarsh (UK) (opens in a new tab)Solar · Watch and alert
You: Tell me when an inverter starts drifting.
Spocky:
12 inverters · heatsink temperature, AC power, ambient · 5-min data, rolling 30 days
- Rule
- Heatsink temperature vs the 11 other inverters
- Runs
- Every hour
- Alert at
- +10 °C
- Then
- Email, a person confirms
INV-09 heatsink, °C above fleet median
Spocky alert · Nov 25, 14:02
INV-09 heatsink is drifting
7.1 °C above the other inverters, rising 0.5 °C a day, output unchanged so far. Check the cooling fan and air filter. Nothing happens until you confirm.
Met-ocean · Data check
You: Can I trust my buoy sensors?
Spocky:
12 buoys · wave height, wind speed, air and water temperature, pressure · 10-min data, 7 days · 60,480 points
- B-07 · wave heightFrozen at 1.42 m, 412 identical readingsNov 19, 06:00
- B-12 · all signalsSilent, last message 20:50 UTC6 h
- B-03 · air temperature61.3 °C, sensor range −40 to 50 °CNov 24, 13:10
Frozen: same value for 6 h or more · Silent: no message for 1 h · Range: sensor specification
Food process · Batch check
You: Did every batch hold 72 °C for 15 seconds last week?
Spocky:
2 pasteurisation lines · hold temperature, hold time, flow · every batch, last 7 days · 42 batches
- B-1187 · line 271.4 °C for 11 s: flow spike at startTue 03:40
- B-1203 · line 1Hold time 13 s: divert valve late by 2 sThu 22:15
Cross-checked with the batch records
66 of 70 answers validatedFood-process proof of concept
The answers above are drawn from Spocky’s output; names and values are examples. Each demo answers live on public data.
Why not the MCP server of your database?
Cost per question, 77 heat pumps